Skip to content

Measuring Flow- and Setting-Time for Three-Dimensionally Printed Mortar (2021-11)

Case Study

10.14359/51734152

Xu Emily, Tejada Karin, Walker David, Zivkovic Sasa, Hover Kenneth
Journal Article - ACI Materials Journal, Vol. 118, Iss. 6, pp. 395-406

Abstract

The authors explored the influence of ingredients on fluid consistency and setting behavior of mortars for three-dimensional (3D) printing using standard test methods typically employed to monitor post-depositional flow and setting time of pastes and mortar from one to several hours after batching. With minor modifications in method and reanalysis of results, readily available standard tests can characterize some behaviors of plastic mortar as early as half an hour or sooner following printing. The work also showed the behavioral sensitivity of the 3D-printed mortar to changes in ingredients, including conversion of a prebagged commercial mortar mixture to a sand, cement, and lime mixture and isolating the impact of hydrated lime, high-range water reducer, calcium chloride set accelerator, and polypropylene fibers. Fluidity and setting behavior were monitored with the ASTM C1437 mortar flow, ASTM C403 time of setting, modified C403, and ASTM C807 Modified Vicat Needle tests.

BibTeX
@article{xu_teja_walk_zivk.2021.MFaSTfTDPM,
  author            = "Emily Xu and Karin Vanessa Tejada and David Walker and Sasa Zivkovic and Kenneth C. Hover",
  title             = "Measuring Flow- and Setting-Time for Three-Dimensionally Printed Mortar: Case Study",
  doi               = "10.14359/51734152",
  year              = "2021",
  journal           = "ACI Materials Journal",
  volume            = "118",
  number            = "6",
  pages             = "395--406",
}
Formatted Citation

E. Xu, K. V. Tejada, D. Walker, S. Zivkovic and K. C. Hover, “Measuring Flow- and Setting-Time for Three-Dimensionally Printed Mortar: Case Study”, ACI Materials Journal, vol. 118, no. 6, pp. 395–406, 2021, doi: 10.14359/51734152.

Xu, Emily, Karin Vanessa Tejada, David Walker, Sasa Zivkovic, and Kenneth C. Hover. “Measuring Flow- and Setting-Time for Three-Dimensionally Printed Mortar: Case Study”. ACI Materials Journal 118, no. 6 (2021): 395–406. https://doi.org/10.14359/51734152.